INSTALLATION AND OPERATING INSTRUCTIONS
VARI-PAK
CYCLING DC MOTOR CONTROL
Designed for Indexing Applications –
© 2003 KB Electronics, Inc.
OLSTOPON
JOG / STOP
RUN
DC MOTOR SPEED CONTROL
VARI-PAK
NEMA-12
100
90
80
70
60
40
30
20
10
0
50
%
144 S. Wolf Rd
Wheeling, IL 60090
(847) 459-5200
See Safety Warning on Page 2
The information contained in this manual is intended to be accurate. However
, the manufacturer
retains the right to make changes in design which may not be included herein.
This manual covers the following CAMCO part numbers:
92A61633010000, 92A61633020000, 92A61633030000, 92A61633040000
92A81359000000
Industrial Motion Control, LLC
Zobrazit stránku 0
1 2 3 4 5 6 ... 23 24

Shrnutí obsahu

Strany 1 - VARI-PAK

INSTALLATION AND OPERATING INSTRUCTIONSVARI-PAKCYCLING DC MOTOR CONTROL– Designed for Indexing Applications –© 2003 KB Electronics, Inc.OLSTOPONJOG /

Strany 2

8II. MOUNTINGMount the control in a vertical position on a flat surface. Be sure to leave enough room belowthe bottom of the control to allow for the

Strany 3 - JUMPER J1 SETTING vs

Failure to follow the Safety Warning Instructions may result in electric shock, fire or explosion.Do not fuse neutral or grounded conductors. Note: S

Strany 4

1. Remote Potentiometer. Connect remotepotentiometer wires to terminals P1, P2and P3, so that the “high” side of thepotentiometer connects to P3, the

Strany 5 - TABLE 1 – ELECTRICAL RATINGS

B. ”JOG” (Stop) –A maintained contactclosure between terminals “JOG” and“RTN” will cause the control to runcontinuously. This is not a latchingfuncti

Strany 6

12E. +24 VDC SUPPLY – The +24V terminal provides a nominal124 VDC @ 12 mA output foruse with an external load such as one solid-state 3-wire proximity

Strany 7 - L2L1A2A1

13Capable of switching 30 VDC, at 24 mA,with an off-state leakage current of lessthan 1 mA. (See figure 12.) Warning!Do not ground or short +24V to

Strany 8 - KBPI RELAY

14The “Cycle on Demand” function isrequired for most indexing table applica-tions. The control can be easily set forthis operation as follows:1. Jump

Strany 9

15VIII. APPLICATION WIRING DIAGRAMS (Reversible Models)P/N 92A61633020000 (120 VAC) – P/N 92A61633040000 (240 VAC).Reversing models carry out the same

Strany 10 - MOTOR HORSEPOWER

16After the control has been set up properly (the jumpers set to the desired positions and thewiring completed), the start-up procedure can begin. I

Strany 11 - A1 A2 L1 L2

WARNING! Do not adjust trimpots with main power on if possible. If adjust-ments are made with power on, insulated adjustment tools must be used and

Strany 12 - See section IV

TABLE OF CONTENTSSection Pagei. Simplified Operating Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Strany 13 - UN JOG STP RTN +24V COM

C. Overload Indicator (OL) – When the motor is loaded to the current limit setpoint (CL set-point is established by the setting of jumper J1 and the C

Strany 14 - Example 1:

XII – TROUBLESHOOTING GUIDEMOTOR WILL NOT RUN:1. Check control operation by placing RUN - JOG/STOP in RUN position.2. Make sure disconnect fuses or ci

Strany 15 - FIGURE 14A – ROLLER GEAR UNIT

20NCSTOPJWCON1 CON2P3P2P1R SJOG FWDRUN FWDJOG REVRUN REV(8)(7)(6)(5)MIN MAX CL IR10ANOJ13.3A2A5ATB1(2)(4)RTN(3)+24VFCOMOJRRB1RB2JS180V90VJ3KBPI 120V24

Strany 16

– NOTES –21

Strany 17

INDUSTRIALMOTION CONTROL, LLC1444 SOUTH WOLF ROADWHEELING, IL60090 USATel: 847-459-5200 Toll-Free: 800, 645-5207

Strany 18 - LS1 (N/C)

i. SIMPLIFIED OPERATING INSTRUCTIONSA. AC Power –Use 120Volt AC rated controls on120 Volts AC and 240Volt AC rated controls on240 Volts AC. ConnectAC

Strany 19

I. INTRODUCTIONThe VARI–PAK Series is housed in a rugged die cast aluminum NEMA 12 enclosure. Thecontrols are designed specifically for cycling and i

Strany 20

3IMPORTANT! Control part number and ratings must correspond to the AC line voltage, motor voltage and type of operation (Unidirectional or Reversing).

Strany 21

4TABLE 2 – GENERAL PERFORMANCE SPECIFICATIONS100 250TIME (msec)DECEL WITH DYNAMIC BRAKEMOTOR BASE RATED SPEEDFIXEDACCELSPEED(rpm)1800FIGURE 1 – TYPICA

Strany 22 - BPI RELAY

5RB2 RB1P1 P2 P3CON1120VL2L1A2A1TB2J2B J2ARSJWCON2240VMIN MAX CL IRP4J390V 180VJSNC NO3.3AJ12AKBPI10A5AOFJRTB1(3)(2)COM(1)+24V(6)JOG FWDSTOPRTN(4)(5)R

Strany 23 - – NOTES –

6RB2 RB1(6)(2)(1)COMJROFTB1+24V(3)RTN(4)(5)JOG FWDSTOPP1(7)(8)RUN REVJOG REVRUN FWDP2 P3CON1120VL2L1A2A1TB2J2B J2A5A2A3.3A10A90VJ3180VNCJSNOKBPIRSJWCO

Strany 24

7FIGURE 3 – MECHANICAL SPECIFICATIONS (Inches / [mm])RECOMMENDED MOUNTING SCREW: 1/4" (M6)[127.00]5.000[138.99]5.472[149.50]5.886[9.07]0.357[208.